Significance

Prior to the development of MRI, Mansfield and Grannell proposed NMR diffraction (NMRd) as a method to investigate the structure of crystalline materials. When realized on the atomic scale, NMRd would be a powerful tool to study the structure of materials, utilizing the spectroscopic capabilities of NMR. The main challenge to achieving this goal lies in the ability to encode large relative phase differences between neighboring nuclear spins on the atomic scale. Utilizing key advances in nanoMRI technology, we demonstrate the ability to encode and detect angstrom-scale modulation of approximately 2 million 31P spins in an indium-phosphide (InP) nanowire with subangstrom precision. The work represents a significant step toward the realization of atomic-scale NMRd.

Abstract

We have combined ultrasensitive force-based spin detection with high-fidelity spin control to achieve NMR diffraction (NMRd) measurement of ~2 million 31P spins in a (50 nm)3 volume of an indium-phosphide (InP) nanowire. NMRd is a technique originally proposed for studying the structure of periodic arrangements of spins, with complete access to the spectroscopic capabilities of NMR. We describe two experiments that realize NMRd detection with subangstrom precision. In the first experiment, we encode a nanometer-scale spatial modulation of the z-axis magnetization of 31P spins and detect the period and position of the modulation with a precision of <0.8 Å. In the second experiment, we demonstrate an interferometric technique, utilizing NMRd, to detect an angstrom-scale displacement of the InP sample with a precision of 0.07 Å. The diffraction-based techniques developed in this work extend the Fourier-encoding capabilities of NMR to the angstrom scale and demonstrate the potential of NMRd as a tool for probing the structure and dynamics of nanocrystalline materials.
Scattering techniques that employ coherent sources, such as X-rays, neutrons, and electrons, are universal tools in many branches of natural science for exploring the structure of matter. In crystalline materials, these approaches provide a direct and efficient means of characterizing the periodicity of charge and magnetic order. MRI, like other scattering approaches, is a reciprocal space technique, in which the measured signal is proportional to the Fourier transform of the spin density. This similarity between MRI and scattering was recognized very early in the development of MRI and led Mansfield and Grannell in 1973 to propose NMR “diffraction” (NMRd) as a method for determining the lattice structure of crystalline solids (13), taking advantage of the chemical specificity of NMR.
The main challenge to achieving atomic-scale NMRd lies in the difficulty of generating a sufficiently large wavenumber k, capable of encoding a relative phase difference as large as 2π between adjacent spins on a lattice, separated by angstrom-scale distances. For example, the largest encoding wavenumbers achieved in clinical high-resolution MRI scanners are of order k/(2π)~104m1, more than a factor of 105 smaller than what is needed to measure typical atomic spacings in condensed-matter systems (4). Consequently, while MRI has become a transformative technique in medical science, earning Sir Peter Mansfield and Paul Lauterbur the Nobel Prize in Physiology and Medicine, the original vision of NMRd as a method for exploring material structure has not yet been realized.
The realization of atomic-scale NMRd would be a powerful tool for characterizing periodic nuclear spin structures, combining the spectroscopic capabilities of NMR with spatial encoding at condensed matter’s fundamental length scale. NMRd is a phase-sensitive technique that permits real-space reconstruction of the spin density, without the loss of phase information common to scattering techniques, such as X-rays, that measure the scattered-field intensity (5). Being nondestructive and particularly sensitive to hydrogen, NMRd could be of great importance in the study of ordered biological systems, such as protein nanocrystals that are of great interest in structural biology (6, 7). Furthermore, the combination of scattering with NMR’s rich repertoire of spectroscopic tools opens additional avenues for spatially resolved studies of nuclear-spin Hamiltonians (e.g., chemical shifts or spin–spin interactions), which are currently achieved only through increasingly complex and indirect methods (8). Finally, NMRd could be used to study quantum many-body dynamics on the atomic scale. NMR scattering experiments have previously been used in the direct measurement of spin diffusion in CaF2 on the micrometer scale (9). Experiments on many-body dynamics have also been conducted in engineered quantum simulators, such as ultracold atoms (1012), trapped ions (1315), superconducting circuits (1618), and quantum dots (19). However, these measurements have thus far been limited to small-scale quantum systems that are at most hundreds of qubits. Angstrom-scale NMRd measurements would permit studying the dynamics of complex large-scale spin networks in condensed-matter systems on length scales as short as the lattice spacing.
Over the past two decades the principal technologies needed to encode nuclear spin states with wavenumbers of order 1 Å1 have been developed in the context of force-detected nanoMRI (2026). In this work, we report two experiments that utilize key advances in nanoMRI technology—namely the ability to generate large time-dependent magnetic-field gradients and the ability to detect and coherently control nanoscale ensembles of nuclear spins (2731)—to generate encoding wavenumbers as large as k/(2π)~0.48 Å1.
Our first experiment demonstrates the use of spatial spin-state modulation that encodes position information the way it was envisioned in the initial NMRd proposal. Phase-sensitive NMRd detection enables us to determine the position and period of a “diffraction grating” with a precision of <0.8 Å. The diffraction grating itself is a z-axis 31P spin magnetization modulation, the mean period of which is 4.5 nm in our (50 nm)3 detection volume. Our second experiment utilizes spatially modulated spin phase in an alternative way—as a label for the physical displacement of the spins. Our interferometric technique detects an angstrom-scale displacement of the indium-phosphide (InP) sample with a precision of 0.07 Å.

Principles

NMRd Concept.

To illustrate the basic concept of NMRd as envisioned in ref. 1, we consider a one-dimensional spin density having a spatially periodic modulation—such as a linear spin chain with spacing a as shown in Fig. 1—that evolves in a uniform field gradient Gx=B/x for a time τe. The wavevector corresponding to the helical winding encoded in the spins is kx=γGxτe, where γ is the spin gyromagnetic ratio. At particular encoding times τecho=2πl/(γGxa), corresponding to kxa=2πl, the relative phase between neighboring spins becomes Δφ=2πl,l{1,2,3,} and a “diffraction echo” (DE) is observed. At the peak of the echo, the signal from each spin adds constructively, in exact analogy to the diffraction peak observed in a scattering experiment. The lattice constant is determined from the location of the DE peak and the shape of the sample from the Fourier transform of the DE envelope. Because the encoding wavevector is spin selective, the structure factor corresponding to each NMR-active nucleus can be determined separately. The NMRd concept illustrated in Fig. 1 can be readily generalized to three dimensions, with k=γGτe and G=B, where B represents the magnitude of either the static or the radio frequency (RF) field at the Larmor frequency, used for phase encoding. The diffraction condition in three dimensions corresponds to k·aj=2πl, where aj are the primitive vectors of the lattice.
Fig. 1.
Time evolution of a one-dimensional periodic lattice of spins, starting from a uniform z state at τe=0, under a linearly varying external field along the lattice. Each time slice represents an ensemble nuclear spin state with a well-defined k vector. The x, y, z coordinate axes on the left mark the Bloch sphere directions for the spins represented by the cones. For τe>0, the spins dephase and the expectation value of the z-axis magnetization Mz drops to zero. Once the spins on adjacent lattice sites complete a full rotation (Δφ=2π), the spins rephase and a diffraction echo in Mz appears.
Being particularly sensitive to hydrogen atoms, NMRd could enable structural characterization of nanocrystalline organic solids via NMR. For example, a lattice of 1H spins with a=3 Å evolving under a uniform field gradient of 105 T/m would produce a DE at τe=780 μs. While the dephasing times in most organic solids are much shorter, typically of order T2~20 μs, dynamical decoupling NMR pulse sequences, such as the symmetric magic echo sequence (32), can be used to extend the coherence time into the millisecond range, while allowing for encoding with both static and resonant RF field gradient pulses. Importantly, although the concept of NMRd was first envisioned as a technique to study crystal structures, it can be applied more broadly to probe any spatially periodic spin-state modulation, e.g., a periodic modulation of the z-axis magnetization, that can be refocused by the evolution under the field gradient. The magnetization modulation could, for example, also arise from evolution under internal spin Hamiltonians such as spectroscopic shifts or spin–spin interactions, both of which could be studied on atomic length scales.

Experimental Setup.

The experimental setup, shown in Fig. 2A, is similar to the one used in our previous nanoMRI work (24). Force-detected magnetic resonance measurements were performed using a silicon nanowire (SiNW) mechanical resonator, which served as the mechanical sensor to detect the force exerted on 31P spins in an InP nanowire (InPNW) placed in a magnetic-field gradient. The InPNW sample was attached to the SiNW resonator with the axes of the two nanowires aligned parallel to each other. To apply various control signals to the SiNW, we glued the SiNW chip to a millimeter-size piezo electric transducer (PT). To increase the measurement bandwidth of the resonator, a feedback signal was applied to the PT (33). For details of the SiNW and InPNW growth and attachment, see Materials and Methods and SI Appendix.
Fig. 2.
(A) Schematic of the experimental setup, including the SiNW force sensor, the CFFGS, and the InP spin sample. (B) Simulated contours of constant Rabi frequency u(r). The contours within the sample are nearly parallel to the xy plane and vary primarily in the z direction.
NMR measurements were performed by applying a static field of B0=3 T parallel to the the InPNW axis. At this field, the Larmor frequency of the 31P spins is ω0/(2π)=51.7MHz. The time-varying magnetic fields and magnetic-field gradients used for spin measurements were generated using a current-focusing field gradient source (CFFGS) (Materials and Methods). All measurements were carried out with the tip of the InPNW placed at the center of the CFFGS and positioned ~50 nm above the surface.
The transverse field in the rotating frame B1(r)=Bx2(r)+By2(r)/2 used for NMR was produced by driving the CFFGS with 70 mA-peak currents at ω0, where Bx(r),By(r), and Bz(r) are the components of the magnetic field at position r. Correspondingly, each spin has a Rabi frequency u(r)=γB1(r)/(2π), where γ/(2π)=17.235 MHz/T is the 31P gyromagnetic ratio. Further details regarding the field profile produced by the CFFGS are provided in SI Appendix.

Results

Nanometer-Scale NMRd Measurements.

To observe a focused diffraction echo—i.e., one in which the spectral weight of the echo is localized within a narrow range of encoding times—the spin-state modulation must be a periodic function of the encoding-field coordinate; e.g., for a spin density with a spatially periodic modulation, the encoding-field profile must vary linearly in space as in Fig. 1. As a demonstration of nanometer-scale NMRd, we utilize the B1 gradient to 1) create a diffraction grating by periodically inverting the z-axis magnetization of the 31P spins within the measured volume of the InP tip (Fig. 3) and 2) generate the encoding wavevector for the NMRd measurements. In so doing, we ensure that the spin modulation is a periodic function of the encoding field.
Fig. 3.
(A) Spatial configuration of the InP spin sample brought 50 nm above the surface of the CFFGS device. The CFFGS surface lies perpendicular to the static external magnetic field B0 z^. The 18 regions indicated in red represent the regions inverted by the band-inversion pulses within g(u). (Inset) Scanning electron microscope (SEM) image of a representative InPNW. The measured volume of the sample is indicated by the outlined region. (B) Measured weighted Rabi-frequency distribution p(u) of the 31P spins in the detection volume indicated by the outlined region in A, Inset. The data were obtained by sampling 20 points in the frequency range 0u1 MHz. The upper horizontal axis indicates the z coordinate corresponding to the particular u value on the InPNW axis at the center of the CFFGS (x=y=0). (C) Calculated inversion profile h(u) for the 100-kHz-wide band-inversion pulse, targeting spins in the Rabi frequency range 562.5 kHz u 662.5 kHz. (D) Spin signal measured after applying the band-inversion profile shown in C. The data were obtained by sampling 23 points in the frequency range 325 kHzu875 kHz. The solid green line indicates the expected distribution calculated using the measured p(u) in B and the calculated h(u) in C.
We detect the statistical spin fluctuations in an ensemble of approximately 2×106 31P spins within the conical region of the InP sample indicated in Fig. 3 A, Inset, using the modulated alternating gradients generated with currents (MAGGIC) spin detection protocol described in SI Appendix and ref. 24. The measured spin signal is proportional to the quantity sd3r n(r)GR2(r)χ(u(r))Tr[σzϱf(r)], where n(r) is the spin density, GR(r)=Bz(r)/y is the readout gradient applied in the MAGGIC protocol that couples the z-axis magnetic moment of a spin at position r to the resonant mechanical motion of the SiNW, and χ(u) is a Rabi-frequency–dependent filter function used to control the detection volume (SI Appendix). Here, ϱf(r) is the traceless part of the density matrix of the spin at position r at the end of the NMR control sequence, Tr[σzϱf(r)] is proportional to the expectation value of the z-axis component of the magnetic moment of the spin, and (σx,σy,σz) are the Pauli spin operators.
For the case where the NMR control sequence is only selective in Rabi frequency, ϱf is only a function of u, such that s0du p(u)Tr[σzϱf(u)], where p(u) is the weighted Rabi frequency distribution, determined by the sample geometry, the readout gradient GR(r), and the filter function χ(u). For a derivation of p(u) in terms of the MAGGIC protocol parameters, see SI Appendix. We experimentally determine p(u) (Fig. 3B) using the Fourier-encoding method presented in ref. 24.
We encode the periodic grating g(u) in the z-axis magnetization by selectively inverting sequential regions in the sample that are 10.2-kHz wide and separated by 10.2 kHz in u, as indicated in Fig. 4A. The physical regions targeted by the inversions are shown in Fig. 3A. To generate a particular g(u), we implement control waveforms that invert spins within the range (ulow,uhigh) with adjustable edge sharpness around ulow and uhigh. To verify the performance of the inversion waveform, we implement a control sequence that inverts spins within a 100-kHz bandwidth: 562.5kHzu662.5kHz. The calculated inversion profile is shown in Fig. 3C. The measured spin signal after the application of the band-inversion pulse (Fig. 3D) agrees closely with the expected inversion profile. Further details regarding the design of the band-inversion pulses are in SI Appendix. We also include an animation depicting the operation of the 100-kHz-wide band-inversion pulse in Movie S2.
Fig. 4.
NMRd data measured for the 18× diffraction grating. (A) Inversion profile for the two positions (g1 and g2) of the periodic grating encoded with a period of 20.4 kHz. The top horizontal axis indicates the position dependence of g1 and g2 with respect to the CFFGS. The shift in position corresponding to Δu=4.74 kHz is indicated for the regions of the sample that are 50 and 140 nm away from the CFFGS. (B) Calculated in-phase component sI(τ) for the grating at position 1 given the simulated g1(u) profile in A and measured p(u) shown in Fig. 3B. (C) NMR control sequence. The encoding part of the sequence generates either g1(u) or g2(u) in A by applying 18 consecutive inversions. The second part of the sequence performs the NMRd readout. sI(τ) is measured by applying a resonant RF pulse (x) for a duration τ. An extra adiabatic half-passage pulse is applied for detecting the quadrature component sQ(τ). (D and E) sI(τ) and sQ(τ) measurements for the two grating positions in A as a function of the effective encoding time τ. The shaded regions in D and E indicate the signal amplitude. (F and G) Coordinate–space reconstruction of the diffraction grating. Solid lines in F and G are the calculated p(u)g1(u) [p(u)g2(u)] using g1(u) [g2(u)] in A and p(u) in Fig. 3B. The data points are the coordinate–space reconstructions of p(u)g1(u) and p(u)g2(u) by Fourier transforming the data in D and E after zero padding. The position values indicated on the lower horizontal axis are determined from the simulated field distribution produced by the CFFGS (SI Appendix). The dashed vertical lines are placed as a guide to indicate the spatial offset between the two grating positions. The number of the inversion slice is indicated above the vertical lines.
Movie S2.
Animation depicting the operation of the 100 kHz-wide band inversion waveform.
The NMR control sequence used to measure g(u) is shown schematically in Fig. 4C. After encoding the grating, we apply a Larmor-frequency RF pulse for a duration τ.* The evolution of the spin, when driven with constant Rabi frequency u, is described by a unitary U(u,τ)=exp(i2πuτσx/2) in the frame rotating at ω0, which yields ϱf(u)=g(u)U(u,τ)σzU(u,τ)/2=g(u)[cos(2πτu)σzsin(2πτu)σy]/2. The in-phase (sI) and quadrature (sQ) components of the diffraction signal are
[sI(τ)sQ(τ)]0dup(u)g(u)[cos(2πuτ)sin(2πuτ)].
[1]
To measure the quadrature part of NMRd signal, we end the measurement sequence with a numerically optimized adiabatic half-passage (AHP) pulse (34) that rotates σy to σz. It can be seen that if g(u) has a single modulation period Ω, i.e., g(u+lΩ)=g(u),lZ, and varies much more rapidly than the envelope of p(u), then sI(τ) and sQ(τ) contain a series of diffraction echos separated by 1/Ω-long intervals. The amplitudes of these echos reflect the magnitude of the Fourier coefficients of g(u), and the echo envelopes contain the Fourier transform of p(u).
To demonstrate the phase, and consequently position, sensitivity of NMRd, we encode two spin magnetization gratings g1(u) and g2(u), shown in Fig. 4A, that differ by a 4.74-kHz translation; i.e., g2(u)=g1(u+4.74 kHz). We refer to g1(u) and g2(u) as the grating at positions 1 and 2, respectively. The physical displacement of the grating corresponding to Δu=4.74 kHz is Δz=0.7 nm (Δz=1.9 nm) at z = 50 nm (z = 140 nm). Both gratings are produced using the control sequence shown in Fig. 4C that comprises 18 band inversion waveforms sandwiched between two AHPs identical to the ones used to measure sQ(τ).
Fig. 4B shows a plot of the expected sI(τ) calculated using Eq. 1, g1(u), and the measured p(u) shown in Fig. 3B. Because the first DE at τ~49 μs has a significantly larger amplitude than the higher-diffraction orders, we measure the NMRd signal only for l = 1, for both grating positions, in the interval 39 μsτ59 μs, using the NMRd measurement protocol that is shown in Fig. 4C. We note that for all measurements shown in Fig. 4, the maximum duration of the RF pulse used in the NMRd measurement portion of the sequence was 59μs, which is much shorter than the transverse relaxation time T2ρ=570μs measured under a continuous Larmor-frequency excitation (SI Appendix). Therefore, we ignore decoherence effects during the RF pulse in our analysis and simulations. The resulting data are shown in Fig. 4 D and E, which also include the unscaled calculated values for sI(τ) and sQ(τ). The echo envelopes for both signal quadratures are shown as the shaded regions in Fig. 4 D and E. We see that although the small shift in the grating position produces little discernible change in the echo envelope, there is a clearly visible change in the relative phase of the in-phase and quadrature measurements, demonstrating the importance of phase-sensitive detection for high-precision position measurements.
In SI Appendix, we construct a statistical estimator (35) to determine the periodicity Ω from the measured data. The calculation is done assuming no prior knowledge of g(u), other than the fact that it is periodic in u and varies more rapidly than p(u). The resulting estimates for Ω in g1 and g2 are Ω1=20.30±0.14 kHz and Ω2=20.26±0.10 kHz, respectively. The 0.14-kHz (0.10-kHz) error in the period of g1 (g2) in u space corresponds to an uncertainty of 0.2 Å (0.15 Å) in the wavelength of the grating at z = 50 nm and 0.6 Å (0.4 Å) at z = 140 nm.
In SI Appendix, we construct a maximum-likelihood estimator for Δu for the data in Fig. 4, which yields Δu=4.67±0.20 kHz, in excellent agreement with the expected value of Δu=4.74 kHz. The error in Δu corresponds to an uncertainty of 0.3 Å (0.8 Å) in the relative z-axis position of g1 (g2) at z = 50 nm (z = 140 nm).
We reconstruct the periodic spin modulation in spatial coordinates by calculating the real part of the complex Fourier transform Re{F1[sI(τ)+isQ(τ)]} using the data shown in Fig. 4 D and E for the two grating positions. In the reconstruction, we include the points around the l = 1 DE, as well as the points sampled near τ = 0 to account for a small DC offset in the modulation envelope caused by a slight asymmetry in the magnitude of the positive- and negative-amplitude regions in g(u). The time records used in the Fourier transforms are constructed to be continuous by zero-padding the unsampled regions in the interval 0τ59.5 μs (Fig. 4B). The data in the interval 0τ3 μs are not expected to change for the two grating positions. Therefore, this interval was measured only for position 1 and used in the reconstruction of both grating positions. We see that the position–space representations of p(u)g1(u) and p(u)g2(u), shown in Fig. 4 F and G, closely follow the calculated values.

Displacement Detection via NMR Interferometry.

In the previous section, we performed phase-sensitive NMRd measurements of a nanometer-scale periodic modulation of the z-axis magnetization with subangstrom precision. In this section, we describe an interferometric detection protocol that enables us to measure a real-space displacement of the InP sample in the z direction with a precision of 0.07 Å. The protocol, shown schematically in Fig. 5A, utilizes the symmetric magic echo (SME4) (32) NMR sequence to decouple the P-P and P-In interactions, thereby extending the coherence time of the 31P spins up to 12.8 ms. In SI Appendix, we describe a modification to the SME4 that allows us to evolve the spins under the Rabi-frequency gradient u/z=γ(B1/z)/(2π) for a variable amount of time Δτ for phase encoding. By extending the spin coherence time into the millisecond range and by utilizing the large-field gradients (B1/z~2×105 T/m) we encode a helical phase winding in the xz plane with an average wavelength as short as a few angstroms, allowing us to detect displacements of the InP sample with picometer precision.
Fig. 5.
(A) NMR control sequence used for interferometric displacement detection, as well as the voltage VP(t) applied to the PT, and the PT displacement δr(t). The unitary operations corresponding to different parts of the sequence are indicated above each block. The data presented in B and C were acquired from spins in the Rabi-frequency range 400kHz<u<650 kHz, corresponding to the sample volume indicated by the shaded regions in A. The shading indicates the z-axis modulation [cosφ(r,δr0)] at different times during the measurement sequence, corresponding to τe=τd=960μs, and a sample displacement of δr0=1Åz^. (B) The data were acquired using the sequence shown in A, where 2 × SME4 sequences were used in the encoding portion, with each SME4 designed to encode phase for Δτ=480μs. From the fit to the data, we determine the ratio δy/δz=6.5. For reference, two other curves have been included that show the variation in signal amplitude for different ratios of δy/δz. The calculations clearly indicate that for lateral displacements of order 1 nm, a higher ratio δy/δz primarily increases the decay rate with respect to VP of the modulation envelope of the interference signal, without significantly affecting the modulation frequency; the modulation frequency, on the other hand, is primarily determined by δz. The asymmetry in the response along the y and z directions is caused by the relative magnitude of the B1 gradients near the center of the CFFGS, for which B1/x,B1/y0.01B1/z. (C) In-phase and quadrature data were acquired for V P = 0 V and VP=7.2 V with a fixed encoding time of τe=480μs for different decoding times. A single SME4 with Δτ=480μs was used for the encoding and decoding parts of the sequence. The displacement results in a shift in the phase of both signal quadratures. From the fit to the data, we determine displacement corresponding to VP=7.2 V to be δz=0.81±0.07 Å and δy=9.72±1.34 Å. The value of δy determined from the fit is consistent with the value δy=1.0nm determined by optical interferometry (SI Appendix). The VP=7.2 V datasets in C have been offset for clarity.
The protocol starts by encoding a helical winding for a time τe. The traceless part of the density matrix for a spin at position r at the end of the encoding sequence is U[u(r),τe]σzU[u(r),τe]/2, where U[u(r),τ]=exp[i2πτσyu(r)/2]. During this time, a constant voltage is applied to the PT (Fig. 5 B, Inset), which translates the InP sample with respect to the CFFGS, thereby slightly shifting the local field experienced by the 31P spins during encoding. The PT is retracted to its equilibrium position by zeroing the voltage. During retraction, 2 × SME4 sequences with Δτ=0 are applied, contributing no gradient evolution while refocusing the homonuclear dipolar and σz evolution during the time that the PT returns to its equilibrium position. The duration of the 2 × SME4 sequences is 1.8 ms, which is chosen to be substantially longer than the ~300 μs mechanical response time of the PT. In the decoding phase, the inverse unitary U[u(r+δr),τd]=exp[i2πτdu(r+δr)σy/2] is applied for a time τd at the new location of the InP sample, which yields ϱf(r+δr) =δU(r,δr)σzδU(r,δr)/2 =[σzcosφ(r,δr)+σxsinφ(r,δr)]/2, where δU(r,δr)=exp[iφ(r,δr)σy/2]. The differential phase φ(r,δr)=2π[u(r)τeu(r+δr)τd] results from the interference of the encoding and decoding modulations separated by δr. The measured signal quadratures at the end of the sequence are
[sI(τe,τd,δr)sQ(τe,τd,δr)]d3r n(r)GR2(r)χ(u(r))[cosφ(r,δr)sinφ(r,δr)].
[2]
Fig. 5B shows a plot of the in-phase data acquired as a function of the voltage VP applied to the PT, using the sequence shown in Fig. 5A, with τd=τe=960 μs. The modulation wavelength varies from 2.1 to 5.8 Å within the measured volume of the sample. To extract the z displacement from the data, we conduct a least-squares fit (36) using Eq. 2, where we assume that δrVP and δr=δy y^+δz z^, with the fit parameters being the PT coefficient δz/VP and δy/δz. The displacement in the y direction is included because the PT used for the measurements was poled in the y direction; hence δy(VP)δz(VP). The quantity n(r)GR2(r)χ(u(r)) was calculated using our model for the sample geometry (SI Appendix). For details regarding the characterization of the PT, see SI Appendix. The resulting fit is indicated by the solid line in Fig. 5B, corresponding to a displacement δz/VP=0.15±0.01 Å/V. The PT calibration was used to derive the top horizontal axis in Fig. 5B.
Finally, we conduct a set of measurements in which we keep the encoding time and the voltage step applied to the PT constant and vary the decoding time. Fig. 5C shows the in-phase and quadrature data acquired for V P = 0 V and VP=7.2 V with τe=480μs. To extract the sample displacement, we fit to the data using Eq. 2, with the fit parameters being δz and δy (solid lines in Fig. 5C). The fit yields a sample displacement of δz=0.81±0.07 Å. In SI Appendix, we also provide an alternative fitting method, which utilizes the measured p(u) instead of the geometric model of the sample. Consistent with the previous method, the fit yields δz=0.85±0.07 Å.
Using the PT displacement calibration found in Fig. 5B, we would expect the displacement corresponding to VP=7.2 V to be δz=1.04±0.04 Å. Although the calculated displacements from the two measurements are in reasonable agreement, the 20% difference in δz could be caused by systematic errors in the different methods used for determining the displacement corresponding to VP=7.2 V. In particular, to determine the PT displacement for the data in Fig. 5B, we needed to assume a particular functional form for the piezo characteristic δr(VP). For the data in Fig. 5C, however, we find the displacement directly for one particular value of VP, without any assumptions on δr(VP). It is therefore possible that a small nonlinear component in δr(VP) could be responsible for the observed difference.
For measurements that require large encoding wavevectors, such as those that would be needed for crystallographic NMRd, the mechanical stability of the sample becomes an important consideration. We provide an analysis of the effect of mechanical vibrations in SI Appendix, indicating sufficient mechanical stability in the reported experiments.

Discussion

In this work, we have presented two experiments that utilize the large encoding wavevectors generated in a nanoMRI setting to realize phase-sensitive NMRd measurement of 31P spins with subangstrom precision. We believe these results represent substantial progress in establishing NMRd as a tool for studying material structure. With further development of gradient sources capable of applying spatially uniform encoding gradients in three dimensions (3D), NMRd could be used to study the structure of nanocrystalline materials.
Upcoming experiments focusing on NMRd crystallography will utilize a design that combines the CFFGS with four additional current-carrying paths designed to generate highly uniform 3D field gradients of order 3×104 T/m with a maximum variation of 0.5% in a (100 nm)3 volume, suitable for crystallographic NMRd measurements. Using these gradients, 1H spins separated by 3 Å, for example, would form a DE at an encoding time of 2.6 ms, which is readily achievable using dynamical-decoupling NMR sequences, such as the SME. Finally, although the concept of NMRd was first envisioned for the study of material structure, it can be applied more generally to study the dynamics of spatially periodic spin correlations. Here, we have demonstrated the ability to generate encoding wavevectors that could be used to probe spin transport on length scales as short as the lattice spacing.

Materials and Methods

SiNW Resonator.

Arrays of SiNWs were grown epitaxially via the vapor–liquid–solid method from an array of Au catalyst particles patterned near the edge of a 1.5×1×0.4-mm Si(111) substrate. Growth occurred in a H2 and HCl atmosphere using SiH4 as the precursor. The SiNWs had a length of 20 µm and a 100-nm diameter (37). The frequency of the fundamental flexural mode of the as-grown SiNW was ~250 kHz prior to sample attachment and had a spring constant of 0.6 mN/m. At 4 K, the quality factor of the SiNW was ~60,000. After sample attachment, the resonance frequency of the SiNW decreased to 163 kHz; however, no significant change in the quality factor was observed. The effective quality factor of the SiNW was reduced to 700 after feedback damping through the PT.

InPNW Growth.

The InPNW sample used in this work was ~5 µm long, with an ~50-nm diameter, grown with a Wurtzite structure. The growth was done on a SiO2-patterned (111)B InP substrate using chemical beam epitaxy with trimethylindium (TMI) and precracked PH3 and AsH3 sources. The patterned substrate consisted of circular holes opened up in the SiO2 mask using electron-beam lithography and a hydrofluoric acid wet etch into which a 5-nm-thick Au layer was deposited using a self-aligned liftoff process. To achieve precise diameter control, a two-step growth process was employed (38). First, we use growth conditions (e.g., low growth temperature, low TMI, and PH3 fluxes) that promote incorporation of material only at the Au/InP interface (i.e., vapor–liquid–solid epitaxy) and produce defect-free wurtzite phase nanowire cores with a diameter of ~20 nm (39). To clad the nanowire core we switch to conditions that promote material incorporation on the nanowire sidewalls (e.g., higher PH3 flux) to controllably increase the nanowire diameter to ~50 nm (40), see Fig. 3 A, Inset.

Sample Attachment.

The InPNW sample was attached ~3 to 4 µm away from the tip of the SiNW, with the tip of the InPNW extending ~2 µm beyond the tip of the SiNW. Details of the attachment procedure are provided in SI Appendix. A video of the sample attachment is also included in Movie S1.
Movie S1.
Video depicting the attachment of the InP sample to the SiNW.

CFFGS Device.

The CFFGS device was fabricated by electron-beam lithography and reactive ion-beam etching of a 100-nm-thick Al film deposited on a sapphire substrate. The device contained a 150-nm-wide and 50-nm-long constriction, which served to focus electrical currents to produce the magnetic fields used for spin detection and control.

Force-Detected NMR Measurements.

NMR measurements were performed in high vacuum at 4 K using a custom-built force microscope with piezo nanopositioners for relative positioning of the SiNW chip, CFFGS, and the optical fiber, which was used for interferometric displacement detection of the SiNW. For details of the measurement along with a schematic of the experimental setup, see SI Appendix.

Data, Materials, and Software Availability

All study data are included in the article and/or SI Appendix.

Acknowledgments

This work was undertaken due in part to funding from the US Army Research Office through Grant W911NF1610199, the Canada First Research Excellence Fund (CFREF), and the Natural Sciences and Engineering Research Council of Canada. The University of Waterloo’s Quantum-Nano Fabrication and Characterization Facility (QNFCF) was used for this work. This infrastructure would not be possible without the significant contributions of Transformative Quantum Technologies (CFREF-TQT), Canada Foundation for Innovation (CFI), Industry Canada, the Ontario Ministry of Research and Innovation, and Mike and Ophelia Lazaridis. Their support is gratefully acknowledged. H.H. thanks F. Flicker, S. H. Simon, and H. S. Røising for insightful and inspiring discussions. R.B. thanks D. G. Cory and A. Cooper for useful discussions.

Supporting Information

Appendix 01 (PDF)
Movie S1.
Video depicting the attachment of the InP sample to the SiNW.
Movie S2.
Animation depicting the operation of the 100 kHz-wide band inversion waveform.

References

1
P. Mansfield, P. K. Grannell, NMR ‘diffraction’ in solids? J. Phys. C Solid State Phys. 6, L422 (1973).
2
P. Mansfield, P. K. Grannell, “Diffraction” and microscopy in solids and liquids by NMR. Phys. Rev. B 12, 3618–3634 (1975).
3
P. Mansfield, Snapshot magnetic resonance imaging (Nobel lecture). Angew. Chem. Int. Ed. Engl. 43, 5456–5464 (2004).
4
B. Vachha, S. Y. Huang, MRI with ultrahigh field strength and high-performance gradients: Challenges and opportunities for clinical neuroimaging at 7 T and beyond. Eur. Radiol. Exp. 5, 35 (2021).
5
H. A. Hauptman, The phase problem of X-ray crystallography. Rep. Prog. Phys. 54, 1427 (1991).
6
H. N. Chapman et al., Femtosecond X-ray protein nanocrystallography. Nature 470, 73–77 (2011).
7
M. T. B. Clabbers, J. P. Abrahams, Electron diffraction and three-dimensional crystallography for structural biology. Crystallogr. Rev. 24, 176–204 (2018).
8
A. Klein et al., Atomic-resolution chemical characterization of (2x)72-kDa tryptophan synthase via four- and five-dimensional 1H-detected solid-state NMR. Proc. Natl. Acad. Sci. U.S.A. 119, e2114690119 (2022).
9
W. Zhang, D. G. Cory, First direct measurement of the spin diffusion rate in a homogenous solid. Phys. Rev. Lett. 80, 1324 (1998).
10
I. Bloch, J. Dalibard, W. Zwerger, Many-body physics with ultracold gases. Rev. Mod. Phys. 80, 885–964 (2008).
11
P. N. Jepsen et al., Spin transport in a tunable Heisenberg model realized with ultracold atoms. Nature 588, 403–407 (2020).
12
D. Wei et al., Quantum gas microscopy of Kardar-Parisi-Zhang superdiffusion. Science 376, 716–720 (2022).
13
C. Monroe et al., Programmable quantum simulations of spin systems with trapped ions. Rev. Mod. Phys. 93, 025001 (2021).
14
Q. X. Mei et al., Experimental realization of the Rabi-Hubbard model with trapped ions. Phys. Rev. Lett. 128, 160504 (2022).
15
H. B. Kaplan et al., Many-body dephasing in a trapped-ion quantum simulator. Phys. Rev. Lett. 125, 120605 (2020).
16
K. Xu et al., Emulating many-body localization with a superconducting quantum processor. Phys. Rev. Lett. 120, 050507 (2018).
17
Q. Zhu et al., Observation of thermalization and information scrambling in a superconducting quantum processor. Phys. Rev. Lett. 128, 160502 (2022).
18
Q. Guo et al., Stark many-body localization on a superconducting quantum processor. Phys. Rev. Lett. 127, 240502 (2021).
19
C. J. van Diepen et al., Quantum simulation of antiferromagnetic Heisenberg chain with gate-defined quantum dots. Phys. Rev. X 11, 041025 (2021).
20
C. L. Degen, M. Poggio, H. J. Mamin, C. T. Rettner, D. Rugar, Nanoscale magnetic resonance imaging. Proc. Natl. Acad. Sci. U.S.A. 106, 1313–1317 (2009).
21
J. M. Nichol, E. R. Hemesath, L. J. Lauhon, R. Budakian, Nanomechanical detection of nuclear magnetic resonance using a silicon nanowire oscillator. Phys. Rev. B Condens. Matter Mater. Phys. 85, 054414 (2012).
22
J. M. Nichol, T. R. Naibert, E. R. Hemesath, L. J. Lauhon, R. Budakian, Nanoscale Fourier-transform magnetic resonance imaging. Phys. Rev. X 3, 031016 (2013).
23
K. Arai et al., Fourier magnetic imaging with nanoscale resolution and compressed sensing speed-up using electronic spins in diamond. Nat. Nanotechnol. 10, 859–864 (2015).
24
W. Rose et al., High-resolution nanoscale solid-state nuclear magnetic resonance spectroscopy. Phys. Rev. X 8, 011030 (2018).
25
M. Barbic, Magnetic resonance diffraction using the magnetic field from a ferromagnetic sphere. J. Appl. Phys. 91, 9987–9994 (2002).
26
M. Barbic, A. Scherer, Sample-detector coupling in atomic resolution magnetic resonance diffraction. J. Appl. Phys. 92, 7345–7354 (2002).
27
S. H. Autler, C. H. Townes, Stark effect in rapidly varying fields. Phys. Rev. 100, 703–722 (1955).
28
U. Haeberlen, J. S. Waugh, Coherent averaging effects in magnetic resonance. Phys. Rev. 175, 453–467 (1968).
29
A. Tannús, M. Garwood, Improved performance of frequency-swept pulses using offset-independent adiabaticity. J. Magn. Reson. A 120, 133–137 (1996).
30
M. Garwood, L. DelaBarre, The return of the frequency sweep: Designing adiabatic pulses for contemporary NMR. J. Magn. Reson. 153, 155–177 (2001).
31
H. Haas, D. Puzzuoli, F. Zhang, D. G. Cory, Engineering effective Hamiltonians. New J. Phys. 21, 103011 (2019).
32
G. S. Boutis, P. Cappellaro, H. Cho, C. Ramanathan, D. G. Cory, Pulse error compensating symmetric magic-echo trains. J. Magn. Reson. 161, 132–137 (2003).
33
M. Poggio, C. L. Degen, H. J. Mamin, D. Rugar, Feedback cooling of a cantilever’s fundamental mode below 5 mK. Phys. Rev. Lett. 99, 017201 (2007).
34
S. Tabatabaei et al., Numerical engineering of robust adiabatic operations. Phys. Rev. Appl. 15, 044043 (2021).
35
G. Casella, R. Berger, Statistical Inference (Duxbury Advanced Series, Brooks/Cole Publishing Company, 1990).
36
D Sivia, J Skilling, Data Analysis: A Bayesian Tutorial (Oxford Science Publications [OUP Oxford], 2006).
37
P. Sahafi et al., Ultralow dissipation patterned silicon nanowire arrays for scanning probe microscopy. Nano Lett. 20, 218–223 (2020).
38
D. Dalacu et al., Selective-area vapor-liquid-solid growth of tunable InAsP quantum dots in nanowires. Appl. Phys. Lett. 98, 251101 (2011).
39
D. Dalacu et al., Ultraclean emission from InAsP quantum dots in defect-free wurtzite InP nanowires. Nano Lett. 12, 5919–5923 (2012).
40
D. Dalacu, P. J. Poole, R. L. Williams, Tailoring the geometry of bottom-up nanowires: Application to high efficiency single photon sources. Nanomaterials (Basel) 11, 1201 (2021).

Information & Authors

Information

Published in

The cover image for PNAS Vol.119; No.40
Proceedings of the National Academy of Sciences
Vol. 119 | No. 40
October 4, 2022
PubMed: 36161956

Classifications

Data, Materials, and Software Availability

All study data are included in the article and/or SI Appendix.

Submission history

Received: May 28, 2022
Accepted: August 31, 2022
Published online: September 26, 2022
Published in issue: October 4, 2022

Keywords

  1. magnetic resonance
  2. scattering
  3. MRI

Acknowledgments

This work was undertaken due in part to funding from the US Army Research Office through Grant W911NF1610199, the Canada First Research Excellence Fund (CFREF), and the Natural Sciences and Engineering Research Council of Canada. The University of Waterloo’s Quantum-Nano Fabrication and Characterization Facility (QNFCF) was used for this work. This infrastructure would not be possible without the significant contributions of Transformative Quantum Technologies (CFREF-TQT), Canada Foundation for Innovation (CFI), Industry Canada, the Ontario Ministry of Research and Innovation, and Mike and Ophelia Lazaridis. Their support is gratefully acknowledged. H.H. thanks F. Flicker, S. H. Simon, and H. S. Røising for insightful and inspiring discussions. R.B. thanks D. G. Cory and A. Cooper for useful discussions.

Notes

This article is a PNAS Direct Submission.
*Prior to the application of the RF pulse, we introduce a wait time ~3T2*, where T2*=70 μs, to dephase any small residual transverse components in the spin magnetization that can arise from the band inversion pulses.

Authors

Affiliations

Holger Haas1
Department of Physics and Astronomy, University of Waterloo, Waterloo, ON N2L3G1, Canada
Institute for Quantum Computing, University of Waterloo, Waterloo, ON N2L3G1, Canada
Present address: IBM Quantum, IBM T. J. Watson Research Center, Yorktown Heights, NY 10598.
Department of Physics and Astronomy, University of Waterloo, Waterloo, ON N2L3G1, Canada
Institute for Quantum Computing, University of Waterloo, Waterloo, ON N2L3G1, Canada
Department of Physics, University of Illinois at Urbana–Champaign, Urbana, IL 61801
Pardis Sahafi
Department of Physics and Astronomy, University of Waterloo, Waterloo, ON N2L3G1, Canada
Institute for Quantum Computing, University of Waterloo, Waterloo, ON N2L3G1, Canada
Michèle Piscitelli
Department of Physics and Astronomy, University of Waterloo, Waterloo, ON N2L3G1, Canada
Institute for Quantum Computing, University of Waterloo, Waterloo, ON N2L3G1, Canada
Present address: Clarendon Laboratory, Department of Physics, University of Oxford, Oxford OX1 3PU, United Kingdom.
Andrew Jordan
Department of Physics and Astronomy, University of Waterloo, Waterloo, ON N2L3G1, Canada
Institute for Quantum Computing, University of Waterloo, Waterloo, ON N2L3G1, Canada
Department of Physics and Astronomy, University of Waterloo, Waterloo, ON N2L3G1, Canada
Institute for Quantum Computing, University of Waterloo, Waterloo, ON N2L3G1, Canada
Department of Physics and Astronomy, University of Waterloo, Waterloo, ON N2L3G1, Canada
Institute for Quantum Computing, University of Waterloo, Waterloo, ON N2L3G1, Canada
Ben Yager
Department of Physics and Astronomy, University of Waterloo, Waterloo, ON N2L3G1, Canada
Institute for Quantum Computing, University of Waterloo, Waterloo, ON N2L3G1, Canada
Present address: Oxford Instruments NanoScience, Tubney Woods, Abingdon, Oxfordshire OX13 5QX, United Kingdom.
Advanced Electronics and Photonics Research Centre, National Research Council of Canada, Ottawa, ON K1A 0R6, Canada
Dan Dalacu
Advanced Electronics and Photonics Research Centre, National Research Council of Canada, Ottawa, ON K1A 0R6, Canada
Raffi Budakian5 [email protected]
Department of Physics and Astronomy, University of Waterloo, Waterloo, ON N2L3G1, Canada
Institute for Quantum Computing, University of Waterloo, Waterloo, ON N2L3G1, Canada

Notes

5
To whom correspondence may be addressed. Email: [email protected].
Author contributions: H.H., S.T., W.R., and R.B. designed research; H.H., S.T., W.R., and R.B. performed research; P.S., M.P., A.J., B.Y., P.J.P., and D.D. contributed new reagents/analytic tools; H.H., S.T., W.R., P.P., N.S., and R.B. analyzed data; H.H., S.T., and R.B. wrote the paper; and R.B. supervised the project.
1
H.H. and S.T. contributed equally to this work.

Competing Interests

The authors declare no competing interest.

Metrics & Citations

Metrics

Note: The article usage is presented with a three- to four-day delay and will update daily once available. Due to ths delay, usage data will not appear immediately following publication. Citation information is sourced from Crossref Cited-by service.


Altmetrics




Citations

Export the article citation data by selecting a format from the list below and clicking Export.

Cited by

    Loading...

    View Options

    View options

    PDF format

    Download this article as a PDF file

    DOWNLOAD PDF

    Login options

    Check if you have access through your login credentials or your institution to get full access on this article.

    Personal login Institutional Login

    Recommend to a librarian

    Recommend PNAS to a Librarian

    Purchase options

    Purchase this article to access the full text.

    Single Article Purchase

    Nuclear magnetic resonance diffraction with subangstrom precision
    Proceedings of the National Academy of Sciences
    • Vol. 119
    • No. 40

    Figures

    Tables

    Media

    Share

    Share

    Share article link

    Share on social media